Laboratory Equipment (Used) : AVAILABLE TO SELL
Location: USA, ARLINGTON MASSACHUSETTS
Agilent G1321A FLD Detector.
Agilent G1321A FLD Detector
Description:The Agilent 1100 Series G1321A FLD Fluorescence Detector brings high-sensitivity fluorescence detection to your lab.
This easy-to-use detector provides quantitative data and fluorescence spectra from a single run.
Simultaneous multi-wavelength detection improves sensitivity and selectivity.
Use the spectral information for rapid method optimization and verification of separation quality.
Item Specifics:
Single wavelength operation: 10 fg anthracene LOD, Ex 250 nm, Em 400 nm H20 >500 Raman, Ex 350 nm, Em 397 nm, dark value 450 nm, standard flow cell
Dual wavelength operation: H20 > 300 Raman, Ex 350 nm, Em 397 nm and Ex 350, em 450 nm, standard flow cell
Light source- 20 W Xenon flash lamp, normal mode: 20 W economy mode: 5 W
Pulse frequency- 365 Hz for signal mode, 73 Hz for economy mode
Excitation monochromator- Concave holographic grating, F/1.6, blaze 300 nm, range 200-700 nm and zero-order, bandwidth 20 nm
Photomultiplier-200-600 nm, exchangeable
Wavelength repeatability ±0.2 nm
All our equipment is expertly reconditioned and then tested to perform at factory specifications before being shipped. The turnaround time is 7-10 business days from receipt of a purchase order and payment terms would need to be discussed.. Below is a description of our refurbishing process by our Agilent certified Technician:
HPLC/FPLC Refurbishing Process
Main frame:
• All circuit boards, motors, and power supply are cleaned and inspected for proper operation, replaced as needed.
• Tubing is inspected and replaced as needed.
• All valves are disassembled, cleaned and inspected, rebuilt if necessary.
• Firmware is upgraded to support Workstation Provided.
Pumping System:
• Pumps have been disassembled and inspected for proper operation.
• Wash seals, pump seals have been replaced.
• Plungers are inspected and replaced as needed.
• New inline filter is replaced. Inlet and outlet check valves are replaced or rebuilt.
• Proportioning valves inspected for proper distribution and Replaced if necessary (Multiple solvent Only).
• Transducers have been calibrated.
• High pressure leak tests performed and passed.
Injector, Sampler:
• Injector assembly is disassembled and cleaned.
• Needle, Injection seals, wash seals and frit are replaced.
• Calibration for needle and seal alignment is performed.
• Heater/Chiller (Option) is cleaned and inspected and passed min/max temp test
• New syringe installed and tested.
Detectors
• Clean, rebuild Flow Cells or replace if needed.
• Clean and inspect all electronics.
• Perform required calibration if necessary.
Performance: HPLC grade solvents are used at all times. Machine is run using an industry 4 peak standard to check for proper performance.
Column Compartment: Column oven is cleaned and inspected for proper operation. Temperature test is performed.
Optional valves installed are rebuilt and tested for proper performance.
If you require a formal quote with shipping and handling included please provide me with the exact ship to and bill to addresses and I'll get you one quickly.
Please feel free to contact me if you need additional information or have any questions.
Listing ID: LA991547
|
|