|
Used Medical Equipment : AVAILABLE TO SELL
Location: USA, SYMAR CALIFORNIA
GE CASE STRESS TEST SYSTEM.
COMPLETE GE CASE STRESS TEST SYSTEM WITH TREADMILL AND ALL ACCESSORIES.
Performance Specifications
Instrument type
Unity-enhanced cardiac stress testing system with 14 channel acquisition and programmable, lead configurations. Pentium-based, NT technology platform and hard drive storage delivers local and Catalyst MUSE database access.
Signal Processing
ECG analysis frequency: 500Hz; ST measurements: ST amplitudes, slope, integral, index, ST/HR slope, ST/HR loops, ST/HR index up to 15 leads; E, I and post-I point: Manual or computer selected; Signal processing technique: Incremental median updating; Baseline correction: Cubic Spline or Finite Residual Filter (FRF) algorithm; QRS detection and analysis: Based on automatic or manual lead selection; ECG output: Real-time ECG/QRS beep/TTL synchronization output; Heart rate: Automatic arrhythmia detection, documentation and annotation; Full disclosure ECG: Beat-to-beat record and event review; Reanalysis: Post-test medians remeasurement from E, I, post-I point selections; ECG interpretation: (Optional) 12SL adult and pediatric ECG analysis program; Additional ECG function: Vectorcardiography.
Data Acquisition
Technology: Active, ''Type BF'' floating isolated powered 14 channel acquisition module with built-in leadfail detection and lead prep impedance measurement; Sampling rate: Over-sampling @ 4000 Hz, 12 leads; Dynamic range: 320 mV, + 10mV signal superimposed on + 150mV DC offset; Resolution: 4.88 u V/LSB @ 500 Hz; Noise: <15u V peak-to-peak noise over 0.01 to 150 Hr (-3 dB) bandwidth; Frequency response: -3 dB, display and writer High pass filter: 0.01 (or 0.05 Hz, special use) with DC offset control; Low pass filter: 20, 40, 100, 150 Hz (selectable); Line filter: 50.0 or 60.0 Hz notch filter (selectable); Baseline correction: Cubic spline algorithm; Artifact/baseline correction: FRF algorithm; Common mode rejection:> 140 dB (123 dB with AC filter disabled); Input impedance:> 10MW @ 10 Hz, defibrillator protected; Patient leakage: <10uA Pace detect: Orthogonal LA, LL and V6; 750 uV@ 50us
Communications/Storage
Catalyst MUSE CV system compatible via diskette, network (optional) or modem (optional) MUSE CV Web compatible for retrieval view and printing of Catalyst MUSE CV system data Remote view (optional) of real-time stress test and remote location
Local storage: Minimum 3.2 Gb hard drive storage of complete ECG record and test results
Local network storage (optional)
Listing ID: LA685105
|
|